Why do dust-free workshops need maintenance personnel to maintain?


Release time:

2024-03-26

Author:

Source:

China's purification industry started late, with a large number of foreign companies to our country to establish a production base, or joint venture companies, etc., high-tech skills are changing with each passing day, the requirements for the production environment are getting higher and higher, and the demand for dust-free workshops in various professions has increased significantly. Companies are faced with the continuous increase of output and the increasing competition among occupations, and put forward higher requests for the quality of Dongguan dust-free workshops to meet the intention of high efficiency and low defective rate to achieve profit. Therefore, the purification industry has been rapidly developed in recent years.

Why do dust-free workshops need maintenance personnel to maintain?

China's purification industry started late, with a large number of foreign companies to our country to establish a production base, or joint venture companies, etc., high-tech skills are changing with each passing day, the requirements for the production environment are getting higher and higher, and the demand for dust-free workshops in various professions has increased significantly. Companies are faced with the continuous increase of output and the increasing competition among occupations, and put forward higher requests for the quality of Dongguan dust-free workshops to meet the intention of high efficiency and low defective rate to achieve profit. Therefore, the purification industry has been rapidly developed in recent years.
2, the occupation of their own attention to carry out
In order to serve the needs of dust-free workshops from all walks of life for a long time, experts and scholars in the industry make every effort to organize practitioners to learn and train, and constantly improve their technology to meet higher requirements. In this case, in the past two years, the idea of energy saving has been presented in some good projects. After SARS, everyone began to pay attention to IAQ, and the frequency of activated carbon and photocatalyst increased significantly. A large number of experts have emerged in the industry, and their emergence has greatly improved the quality of the purification industry and made the industry road bright.
3, the builder and the use of the account of the fault.
The professional training in the purification field is basically competing for professionals in the professional field. The limitation of the training scale makes the dust-free workshop lack professional handling personnel for later application. Many of the dust-free workshops have known to find someone to build but no one to take care of them after they are built, resulting in a part of the dust-free workshops with no original name, such as 100, 1000, 10000... The dust-free workshops are qualified when they are built and delivered. After running for a period of time, they show the scene of particle concentration overspending, resulting in a rise in the rate of defective products, and some are even abandoned. If the user does not know the factors that present the above results, he directly thinks that it is the fault of the builders, so the supply and demand sides will be opposed.
4. Demand protection after the completion of dust-free workshop
Most users will find a professional purification engineering company to tailor a dust-free workshop that can meet their production needs. Many people who know about dust-free workshops agree that those who have dust-free workshops for the first time should use better engineering planning companies or they will only waste a large amount of money that is not needed. However, few people who have dust-free workshops will send their managers to receive training in cleaning skills and come back to handle the operation of dust-free workshops. This is their lack of knowledge of the primacy of dust-free protection. It is no wonder that they do not pay attention to it. It is normal for different professions to present such problems. People in the purification industry should assume the responsibility of training and protecting dust-free workshop managers for their customers, and have the responsibility of prompting customers to send people to learn.
5, dust-free workshop demand handling system
The maintenance and control of the cleanliness of Dongguan dust-free workshop requires not only the capital contribution of hardware (equipment), but also outstanding software-handling system to allocate, so as to adhere to outstanding cleanliness. The operation and handling of the dust-free workshop can be discussed according to the operators, raw materials, equipment and things used in the dust-free workshop. In addition to the air conditioning system, the process equipment is also included, system operation protection and maintenance requires trained professionals to perform.
6. Several factors affecting the air quality of dust-free workshop
1) For users, the cleanliness of the dust-free workshop is the focus of their greatest concern. The biggest source of pollution in the dust-free workshop is people and items entering the dust-free workshop. The dust particles in production are also another factor affecting the cleanliness of the room.
2) The reasonable diversion of people and logistics has a primary meaning for the cleanliness of the protection room. Before entering the dust-free workshop, do people change clothes and blow up, do their clothes conform to the specifications of the cleaning management standard, and some personnel with high requirements for cleanliness in production process should bathe before entering? Whether the package is not replaced before entering the dust-free workshop, whether the replaced materials conform to the specifications of the dust-free workshop, etc.
3) The operators in the dust-free workshop shall strictly follow the operating rules of the dust-free workshop. The doors and windows of the dust-free workshop shall be closed at any time. There shall be a buffer zone for the transfer of personnel and articles between the dust-free workshop and the non-dust-free workshop, and there shall be wind bath equipment to prevent the convection of air flow. Personnel unrelated to production shall not enter the dust-free workshop.
4) The ventilation rate of the dust-free workshop and the air supply volume of the air conditioning purification system are the primary internal factors to maintain the positive pressure and cleanliness of the dust-free workshop, but it is restricted by the final resistance of the filters at all levels in the purification system.
5) The equipment in Dongguan dust-free workshop shall be punctual, punctual and fixed for cleaning and protection, and whether the materials and cleaning liquids used in cleaning conform to the rules of dust-free workshop, etc.
6) The dust-free workshop shall test the dust concentration, wind speed, temperature and humidity at the air supply outlet on time, and make a protection plan according to the measurement results. The initial, medium and high efficiency filters in the air conditioning purification system should be replaced according to the change of wind speed and the change of indoor positive pressure.

Key words: